Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Adicionar filtros








Intervalo de ano
1.
Arq. bras. oftalmol ; 83(4): 289-293, July-Aug. 2020. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1131608

RESUMO

ABSTRACT Purpose: Pharmacological pupillary dilation is performed in comprehensive ophthalmological examinations and before biometric measurements. So far, there is no consensus regarding its impact on biometric measurements. This study's aim was to investigate the effects of pharmacological pupillary dilation on ocular biometric measurements in healthy children. Methods: This was a prospective, observational, non-randomized study of children (4-18 years of age) who were admitted for routine ophthalmological examination. Biometric measurements were performed, using a non-contact optical biometry device, both before and after pharmacological pupillary dilation with cyclopentolate hydrochloride. Intraocular lens power calculations were performed using Hill-RBF, Barrett, Olsen, Sanders-Retzlaff-Kraff/Theoretical, Holladay, and Hoffer Q formulas. Descriptive statistical analyses were also performed. The Wilcoxon signed-rank test was used to compare measurements before and after pharmacological pupillary dilation. Relationships between variables were analyzed using the Spearman-Brown rank correlation coefficient. Results: The study included 116 eyes of 58 children (mean age, 8.4 ± 0.32 years; 34 girls). Significant changes were observed after pupillary dilation, compared with before pupillary dilation, in terms of anterior chamber depth, aqueous depth, and central corneal and lens thicknesses. No significant change was observed in axial length. Intraocular lens power calculations revealed no significant changes after pupillary dilation in most formulas except for the Olsen formula. The intraocular lens power was significantly inversely correlated with axial length and anterior chamber depth. Conclusions: Pharmacological pupillary dilation in children appeared to have no impact on axial length and intraocular lens power, but caused a significant increase in anterior chamber depth. The difference in anterior chamber depth measurements before and after pupillary dilation could be related to the optical biometry device model used. These outcomes should be considered in intraocular lens power calculations performed using anterior chamber depth parameters.


RESUMO Objetivo: A dilatação pupilar farmacológica é realizada em exames oftalmológicos abrangentes e antes das medições biométricas. Até o momento, não há consenso sobre seu impacto nas medições biométricas. O objetivo deste estudo foi investigar os efeitos da dilatação pupilar nas medidas biométricas oculares em crianças saudáveis. Métodos: Estudo prospectivo, observacional e não randomizado de crianças (4-18 anos) que foram admitidas para exame oftalmológico de rotina. As medidas biométricas foram realizadas usando um dispositivo de biometria óptica sem contato, antes e após a dilatação pupilar farmacológica com cloridrato de ciclopentolato. Os cálculos de potência das lentes intraoculares foram realizados utilizando as fórmulas de Hill-RBF, Barrett, Olsen, Sanders-Retzlaff-Kraff/ Teórica, Holladay e Hoffer Q. Análises estatísticas descritivas também foram realizadas. O teste dos postos sinalizados de Wilcoxon foi usado para comparar as medidas antes e após a dilatação pupilar farmacológica. As relações entre as variáveis foram analisadas pelo coeficiente de correlação de Spearman-Brown. Resultados: O estudo incluiu 116 olhos de 58 crianças (idade média de 8,4 ± 0,32 anos; 34 meninas). Alterações significativas foram observadas após a dilatação pupilar, em termos de profundidade da câmara anterior, profundidade do humor aquoso e espessura central da córnea e do cristalino. Nenhuma mudança significativa ocorreu no comprimento axial. Os cálculos de potência da lente intraocular não revelaram alterações significativas após a dilatação pupilar na maioria das fórmulas, com exceção da fórmula Olsen. O poder da lente intraocular foi significativamente inversa correlacionada com o comprimento axial e a profundidade da câmara anterior. Conclusões: A dilatação pupilar farmacológica em crianças parece não ter impacto no comprimento axial e no poder da lente intraocular, mas causou um aumento significativo na profundidade da câmara anterior. A diferença nas medidas da profundidade da câmara anterior antes e após a dilatação pupilar pode estar relacionada ao modelo do dispositivo de biometria óptica utilizado. Tais resultados devem ser considerados nos cálculos de potência da lente intraocular realizados usando parâmetros de profundidade da câmara anterior.


Assuntos
Humanos , Masculino , Feminino , Pré-Escolar , Criança , Adolescente , Biometria , Dilatação , Comprimento Axial do Olho/diagnóstico por imagem , Câmara Anterior/anatomia & histologia , Câmara Anterior/diagnóstico por imagem , Refração Ocular , Estudos Prospectivos , Óptica e Fotônica , Lentes Intraoculares
2.
Arq. bras. oftalmol ; 79(2): 92-95, Mar.-Apr. 2016. tab
Artigo em Inglês | LILACS | ID: lil-782813

RESUMO

ABSTRACT Purpose: To analyze intraocular pressure (IOP) and central corneal thickness (CCT) in newborns during the first 12 h of life. Methods: Forty-three newborns born by vaginal delivery (VD) and 30 newborns born by cesarean section (CS) were evaluated. IOP and CCT were measured using Tono-Pen and handheld pachymeter, respectively, at both the 5th minute after delivery and at the 12th h of life. Results: The mean IOP for the VD group was significantly higher than that of the CS group at both the 5th minute and 12th h (p =0.042 and p =0.018, respectively). In both groups, the IOP decreased by the 12th h, but the decrease was only significant for the CS group (p =0.020). The decrease in CCT over the 12 h was significant for both groups (p <0.001). In the VD and CS groups, the IOP values of the males were significantly higher than those of the females at the fifth minute only (p =0.024 and p =0.043, respectively). No other values were significantly different between the genders. Conclusions: Newborn IOP is affected by the mode of delivery and gender. A higher IOP was found in vaginally delivered newborns than in CS newborns for at least 12 h postpartum. CCT showed a significant decline within 12 h. Male newborns have significantly higher IOP values in the first minutes of life.


RESUMO Objetivos: Analisar a pressão intraocular (IOP) e a espessura corneana central (CCT) em recém-nascidos durante as primeiras 12 horas de vida. Método: Quarenta e três recém-nascidos nascidos por parto vaginal (VD) e 30 recém-nascidos nascidos após cesariana (CS) foram avaliados. IOP e CCT foram medidos com Tono-Pen e Handheld Pachymeter no quinto minuto após o parto e na décima segunda hora de vida. Resultados: A média de IOP para o grupo VD foi significativamente maior do que o grupo CS tanto no quinto minuto quanto na décima segunda hora (p=0,042, p=0,018, respectivamente). Em ambos os grupos, a IOP diminuiu na décima segunda hora, mas a redução foi significativa apenas para o grupo CS (p=0,020). A diminuição da CCT nas doze horas foi significativa para ambos os grupos (p<0,001). Nos grupos VD e CS os valores de IOP dos homens foram significativamente maiores do que das mulheres apenas no quinto minuto (p=0,024 e p=0,043, respectivamente). Outros valores não foram significativamente diferentes entre os sexos. Conclusões: A IOP em recém-nascidos é afetada pela via de parto e pelo sexo. A IOP é maior em recém-nascidos de parto normal durante pelo menos 12 horas. A CCT mostra queda significativa no prazo de 12 horas. Recém-nascidos do sexo masculino têm valores de IOP significativamente mais elevados nos primeiros minutos de vida.


Assuntos
Humanos , Masculino , Feminino , Gravidez , Recém-Nascido , Cesárea/efeitos adversos , Fatores Sexuais , Córnea/anatomia & histologia , Parto Obstétrico/efeitos adversos , Pressão Intraocular/fisiologia , Fatores de Tempo , Tonometria Ocular/métodos , Cesárea/métodos , Estudos Prospectivos , Parto Obstétrico/métodos
3.
Arq. bras. oftalmol ; 77(2): 81-83, Mar-Apr/2014. tab
Artigo em Inglês | LILACS | ID: lil-716260

RESUMO

Purpose: To analyze the risk factors, outcomes, demographic characteristics, and attitudes of workers with metallic corneal foreign body (FB) injury. Methods: One hundred consecutive patients who presented with a metallic corneal FB to the eye clinic at Diyarbakir Training and Research Hospital were evaluated. The patients completed a questionnaire and were examined to determine features of the injury. Results: All patients were male. The mean age was 32.46 ± 1.03 years. Fiftyfive percent of the patients were unregistered workers, 59% were working in the metal industry sector, and 65% injuries resulted from metal cutting. Protective goggles were available in the workplace of 64% patients. However, 57% patients were not wearing goggles when the accident occurred, and 43% were injured despite goggle use. Most patients (52%) attempted to remove FBs by themselves. FBs were located in the central zone of the cornea in 16% patients. Rust marks remained after FB removal in 26% patients. Corneal scars from previous FB injuries were present in 58% patients. Only 8% workplaces provided compensation for physician visits for occupation related illnesses. Conclusions: Workplaces with a high risk for eye injuries should increase their protective measures, and educational programs should be implemented for both workers and occupational physicians. The government should enforce laws regarding unregistered workers in a better manner. .


Objetivo: Analisar os fatores de risco, resultados, características demográficas dos trabalhadores e atitudes em relação à lesão por corpo estranho metálico na córnea. Métodos: Foram avaliados cem pacientes consecutivos que se apresentaram com corpo estranho metálico na córnea à clínica oftalmológica do Diyarbakir Training and Research Hospital. Um questionário foi respondido e as características da lesão foram anotadas. Resultados: Todos os pacientes eram do sexo masculino. A idade média foi de 32,46 ± 1,03 anos. Cinquenta e cinco por cento dos pacientes eram trabalhadores não registrados. Cinquenta e nove por cento dos pacientes estavam trabalhando no setor da indústria metal, 65% das lesões resultaram de corte de metal. A presença de óculos de proteção no local de trabalho foi de 64%. Cinquenta e sete por cento dos pacientes não estavam usando óculos de proteção no momento do acidente, e 43% sofreram a lesão, apesar do uso óculos de proteção. Cinquenta e dois por cento dos pacientes tentaram remover o corpo estranho por si só. Dezesseis por cento dos corpos estranhos foram na zona central da córnea. Um depósito de ferrugem permaneceu após a remoção do corpo estranho em 26% dos pacientes. Cinquenta e oito por cento dos pacientes tinham cicatrizes na córnea por causa de lesões por corpo estranho anteriores. Os locais de trabalho que proporcionaram remuneração por visita médica relacionada à ocupação foram de apenas 8%. Conclusões: Locais de trabalho de alto risco devem ser detectados e medidas de proteção devem ser aumentadas. Os programas educacionais devem ser implementados para os trabalhadores e médicos do trabalho. As leis sobre trabalhadores sem carteira assinada ...


Assuntos
Adolescente , Adulto , Humanos , Masculino , Pessoa de Meia-Idade , Adulto Jovem , Acidentes de Trabalho/estatística & dados numéricos , Lesões da Córnea/epidemiologia , Corpos Estranhos no Olho/epidemiologia , Lesões da Córnea/etiologia , Fatores de Risco , Turquia/epidemiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA